| Network standard | Ammendments |
| |
| NUS103 Fire Bans Details the limitations on the use of open flame to be observed by EA personnel and contractors during a rural fire danger period This document is obsolete |
| |
| |
| |
 | NS110 Design and Construction Standard for URDs (281 Kb) Provides the design and construction criteria for 415V and 11kV reticulation systems in Underground Residential Distribution (URD) estates situated within the supply area of EnergyAustralia. |
| |
| |
| |
|  | CIA1102 (20/04/2000), CIA1105 (5/07/2000), CIA1220 (10/04/2002), CIA1243 (23/04/2002), NSA1271 (26/09/2002), NSA1287 (14/02/2003), NSA1293 (26/09/2003), NSA1298 (18/08/2003), NSA1310A (2/10/2003), NSA1324 (1/03/2004), NSA1403 (23/01/2007), NSA1467 (6/05/2008) |
|
 | NS113 Site Selection and Construction Design Requirements for Chamber Substations (311 Kb) Provides minimum site selection, building design and construction requirements for the establishment of new Chamber Substations with ratings up to and including 4.5 MVA. Applies to Surface, Elevated, Upper Level and Basement Chamber Substations, Control Point Chambers and Chambers for High Voltage Customer Connections. Reference drawings |
| |
| |
| |
| NS115 Electrical Construction Standards for Chamber Type Substations Details the criteria for equipping of chamber type distribution substations. This document is obsolete, superseded by NS114 |
| |
| |
 | NS117 Design and Construction Standards for Kiosk Type Substations (204 Kb) Details the criteria for electrical design of kiosk type distribution substations:
This Standard replaces:
NS 117 Design Standards for Kiosk Type Substations, October 1997, as amended,
NS 140 Construction Standards for Kiosk Type Substations Sydney Region, October 1997, as amended,
NS 142 Construction Standards for Kiosk Type Substations – Hunter Region, October 1997, as amended, |
| |
| |
| |
| |
| |
|  | CIA1073 (20/09/1999), CIA1111 (15/06/2000), CIA1181 (4/07/2001), CIA1207 (19/10/2001), CIA1219 (27/11/2001), CIA1221 (7/05/2002), NSA1276 (17/10/2002), NSA1291 (18/03/2003), NSA1299 (18/08/2003), NSA1310A (2/10/2003), NSA1353 (2/05/2005), NSA1366 (10/10/2005) |
|
| |
| |
| |
| |
| |
| |
| |
| NS137 Multi Function Standards (Withdrawn 19 October 2007) Network Standard NS 137 details the design, installation and use of multi-function standards (Smartpoles). This document is obsolete |
| |
| NS140 Construction Standards for Kiosk Type Substations (Sydney) Replaced by: NS 117 Design Standards for Kiosk Type Substations, December 2004 This document is obsolete, superseded by NS117 |
| |
| |
| NS142 Construction Standards for Kiosk Type Substations (Hunter) Replaced by: NS 117 Design Standards for Kiosk Type Substations, December 2004 This document is obsolete, superseded by NS117 |
| |
| |
 | NS145 Pole Inspection and Treatment Procedures (1206 Kb) Describes the inspection, assessment and treatment procedures for timber poles, reinforced poles, concrete and steel poles, lighting standards, lightning masts and water crossing sign supports |
| |
| |
| |
| |
| NUS151 Work In Confined Spaces Details safety procedures to be adopted for work in confined spaces (replaces TS-0500) This document is obsolete |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| NS170 Network Access and Security - OBSOLETE This document is obsolete |
| |
 | NS171 Firestopping in Substations (1109 Kb) Details EnergyAustralia’s specification and requirements for the installation of firestopping materials in openings in substation walls, floors and ceilings |
| |
| |
 | NUS174 Environmental Procedures (101 Kb) Outlines the environmental procedures to be adopted by all personnel involved in the construction, maintenance and operation of EnergyAustralia’s network. |
| |
| |
| |
| |
| |
|  | NSA1275 (26/09/2002), NSA1292 (14/04/2003), NSA1293 (26/09/2003), NSA1315A (20/11/2003), NSA1345 (29/11/2004), NSA1385 (27/04/2006), NSA1417 (2/08/2007), NSA1422 (4/09/2007), NSA1433 (17/10/2007), NSA1437 (10/12/2007), NSA1442 (21/01/2008), NSA1466 (28/04/2008), NSA1479 (9/07/2008), NSA1484 (3/09/2008) |
|
| |
 | NS179 Vegetation Safety Clearances (561 Kb) Covers the vegetation clearance requirements for vegetation in the vicinity of high voltage and low voltage lines, poles, attachments to poles, streetlights, standards and towers. |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
 | NS196 Mobile Generators (208 Kb) NS 196 details the requirements for the connection and operation of Mobile Generators on EnergyAustralia's network |
| |
| |
| |
 | NS204 Communications Pits – Specifications and Installation Guidelines (282 Kb) NS204 provides the specifications and guidelines for the purchase and installation of communication pits (buried and surface) to be used in the EnergyAustralia communications network for fibre optic cable installations, particularly when installed independently of power cable routes. |
| |
| |
| |
 | NS212 Integrated Support Requirements for EA Network Assets (267 Kb) This documents sets out the required support requirements, including documentation, spares and training required for new network assets. This information is required to be delivered with any new type of asset being added to the Network. |
| |
| |